ENGINE MAINTENANCE
MA-21
C
D
E
F
G
H
I
J
K
M
A
B
MA
Revision: 2005 August 2005 350Z
? Do not use wire brush for cleaning.
? If plug tip is covered with carbon, spark plug cleaner may
be used.
? Checking and adjusting plug gap is not required between
change intervals.
INSTALLATION
Installation is the reverse order of removal.
Checking EVAP Vapor Lines ALS000NC
1. Visually inspect EVAP vapor lines for improper attachment and for cracks, damage, loose connections,
chafing and deterioration.
2. Inspect fuel tank filler cap vacuum relief valve for clogging, sticking, etc.
Refer to EC-32, "
EVAPORATIVE EMISSION SYSTEM" .
Cleaner air pressure:
Less than 588 kPa (6 kg/cm
2
, 85 psi)
Cleaning time:
Less than 20 seconds
SMA773C
SMA806CA
Spark plug:
: 24.5 NĚm (2.5 kg-m, 18 ft-lb)