Nissan 350Z Workshop Maunual 2005 (39) PDF | Page 8

SC-8
BATTERY
Revision: 2005 August 2005 350Z
7. Press ?ENTER? to begin the test. Diagnosis results are dis-
played on the tester. Refer to SC-8, "
DIAGNOSTIC RESULT
ITEM CHART" .
8. Press ?ENTER?, then test output code is displayed. Record the
test output code on the repair order.
9. Toggle back to the ?DIAGNOSTIC SCREEN? for test results.
NOTE:
? If necessary, the tester will ask the user to determine if the
battery has just been charged. Choose the appropriate selec-
tion by pressing the up or down arrow button and then press
the ?ENTER? button to make the selection.
? When testing a battery installed in a vehicle that has recently
been driven, select ?BEFORE CHARGE?.
? If the battery has just been slow charged due to a ?CHARGE
& RETEST? decision by the tester, and the tester asks the user ?BEFORE CHARGE/AFTER
CHARGE?, select ?AFTER CHARGE?.
DIAGNOSTIC RESULT ITEM CHART
SEL407X
SEL576X
Diagnostic item Service procedure
GOOD BATTERY
Battery is OK, go to ?Trouble Diagnoses?, ?STARTING SYSTEM?. Refer to SC-15, "
Trouble Diagnoses with
Battery/Starting/Charging System Tester" .
REPLACE BATTERY
Replace battery.
Before replacing battery, clean the battery cable clamps and battery posts. Perform battery test again with
Battery/Starting/Charging system tester. If second test result is ?Replace Battery?, then do so. Perform bat-
tery test again to confirm repair.
BAD CELL-REPLACE
Replace the battery. Perform battery test again with Battery/Starting/Charging system tester to confirm
repair.
GOOD-RECHARGE Perform the slow battery charging procedure. (Initial rate of charge is 10A for 12 hours.)
CHARGE & RETEST
Perform the slow battery charging. (Initial rate of charge is 10A for 12 hours.)
Perform battery test again with Battery/Starting/Charging system tester to confirm repair.
NOTE: